How the roll-up gate works

How the ECN Propagation Tripwire works

This tool grades every open engineering change on five propagation points against a pinned evaluation date. It reads 7 ECNs and rolls them into one verdict — the worst, never the average — then a gate that can only make it worse.

The 7 ECNs

01ECN-1189 · released 2026-03-305 of 5 points landed · 93dPROPAGATED
02ECN-1195 · released 2026-06-051 open point · 26d, inside the 30-day SLAIN FLIGHT
03ECN-1201 · released 2026-05-025 of 5 points landed · 60dPROPAGATED
04ECN-1204 · released 2026-05-255 of 5 points landed · 37dPROPAGATED
05ECN-1207 · released 2026-06-152 open points · 16d, inside the SLAIN FLIGHT
06ECN-1210 · released 2026-06-24, mandatedfix firstmandated · 1 open point (floor stock) · PAST EFFECTIVITY 2026-06-28 — gate firesIN FLIGHT
07ECN-1213 · released 2026-06-29, mandatedmandated · 1 open point · effectivity 2026-08-01, not yet dueIN FLIGHT
ALL CHANGES LANDED
every ECN fully propagated — no open points
CHANGES IN FLIGHT
open points remain but within the 30-day SLA, nothing stranded or past effectivity
BUILDING TO THE OLD PRINT
an ECN is stranded past the SLA, or a mandated ECN is still open on or after its effectivity date
Past-effectivity · worsen-only

A customer- or safety-mandated ECN that is still open on or after its effectivity date forces BUILDING TO THE OLD PRINT however young it is — the effectivity date is the day the old print became the wrong print. Worsen-only: it never lifts a verdict, and it releases the moment the open points close. The SLA runs from release; the gate runs from effectivity — two clocks.

BUILDING TO THE OLD PRINT

Why: Seven ECNs, none stranded — the SLA read alone would be CHANGES IN FLIGHT. But ECN-1210 is mandated, past its 2026-06-28 effectivity date, and still has an open point (floor stock), so the past-effectivity gate forces BUILDING TO THE OLD PRINT. ECN-1213 is also mandated with an open point, but its effectivity is a month out — mandated alone doesn't gate. Two clocks. 0 stranded · 4 in flight · 5 open points · 1 mandated ECN past effectivity · worsen-only.

Fix firstECN-1210 — mandated, past effectivity, one open point (floor stock). Land that point first to release the gate; the verdict then falls to CHANGES IN FLIGHT.

No single ECN is the crisis — the clustering is. The roll-up takes the worst, the gate escalates when trouble compounds, and it names the one thing to fix first. Grades engineering-change propagation from a log you enter — it scores changes, never people, and modifies nothing in your PLM or ERP. Not a compliance determination, not certification of any standard, and not legal advice.